CADDX Ranger 9000E Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Systèmes de contrôle d'accès de sécurité CADDX Ranger 9000E. SXR-64A Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
SXR-64A
Supervised Wireless Receiver
and Zone Expander
Installation Instructions
INTRODUCTION
The Model SXR-64A is a 64-channel, 12-zone, supervised wireless receiver/
annunciator designed for use in residential or commercial security systems. Housed
in a rugged metal enclosure, the SXR-64A connects to a hardwired alarm control
panel adding wireless capability to the panel.
The SXR-64A receives signals from a variety of security transmitters then processes,
displays and transfers the signal to the hardwired alarm control panel. Six unique
conditions for each transmitter channel can be shown on the unit’s display. Conditions
such as “Open Portal”, “Transmitter Low Battery”, “Transmitter Tamper” and “First
Alarm In” show the status of each transmitter in the system. Valuable features such
as Alarm Memory and Transmitter Status allow for quick system diagnosis and
troubleshooting.
The receiver’s eight alarm zones and four supervisory zones provide a fl exible
interface to the alarm control panel. Any or all of the zones can be used. All of the
solid state zone outputs can be either normally open or normally closed electrical
confi guration and can switch up to 100 mA @ 24 VDC.
An easy programming interface using four pushbuttons lets the installer quickly setup
the system. The UP, DOWN, ADVANCE and MEMORY buttons are located inside the
receiver case and are used for transmitter and system programming.
An on-board, high-gain, superheterodyne radio receiver gives the SXR-64A excellent
reception. The MODE indicator shows RF activity. The local whip antenna (supplied)
or remote external antenna (Model EXA-1000) connects to the receiver through a
standard type “F” connector.
The SXR-64A decodes Linear’s SX, S1, and MegaCode™ format transmitters. The
SXR-64A can be used as a direct replacement for Linear’s SS-32, SSR-32, & SXR-64
receivers with an installation bonus of being able to use up to 64 transmitters in the
system.
Power for the SXR-64A is provided from the alarm control panel. To control the alarm
memory, reset tamper and status alert conditions, an armed input on the receiver
connects to an armed output from the control panel.
FEATURES
64 Programmable Transmitter Channels
8 Alarm Zones
4 Supervisory Zones
Rugged Metal Enclosure
Six Condition Displays for Each Transmitter
Alarm Memory with First-Alarm-In
Automatic Supervised Operation
Transmitter Contact State Monitoring
Transmitter Tamper Monitoring
Transmitter Low Battery Monitoring
Transmitter Status Report Monitoring
Easy Installer Programming Interface
High-gain Superheterodyne Receiver
Receiver Automatic Gain Control
Antenna Connector
Decodes 303.875 MHz SX, S1, & MegaCode™ Format Transmitters
Optional Display Blanking while Armed
RF Activity Indicator
Positive or Negative Armed Input
SYSTEM OVERVIEW CONDITION DISPLAYS COMPONENT LOCATIONS
INSTALLATION TIPS MOUNTING UNIT ANTENNA INSTALLATION
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
TERMINAL BLOCK DETAILS TYPICAL CONTROL PANEL CONNECTION S1 FORMAT TRANSMITTER DETAILS
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,SXR-64A - LINEAR P/N: 220822 A - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 17.000” - SCALE: 1-1 - SIDE 1 OF 2
TYPICAL TRANSMITTERS
TX-91 TX-92 TX-94 T-90D TMD-90 TSD-90A
SXR-64A RECEIVER ALARM CONTROL PANEL
UP TO 64 TRANSMITTERS
CAN BE USED
ST-23A LMT-1/303 MPX/303
CONDITIONS FOR ALL TRANSMITTERS
ROTATE ON THE DISPLAY
OPEN PORTAL
ALL TRANSMITTERS WILL CAUSE THIS CONDITION WHEN AN ALARM SIGNAL IS
SENT. THE CONDITION WILL REMAIN UNTIL A RESTORE SIGNAL IS SENT, UNLESS
THE TRANSMITTER IS SET AS "AUTO RESTORE". THE CHANNEL'S ZONE OUTPUT
WILL BE FAULTED WHEN THIS CONDITION IS DISPLAYED.
WHEN THE PANEL IS ARMED, THE FIRST ALARM SIGNAL SENT WILL CAUSE THIS
CONDITION. IF THE CHANNEL IS SET AS "DELAYED", THIS CONDITION WILL OCCUR
AFTER ANY DELAYS IF THE PANEL IS NOT DISARMED. DISPLAY WILL CLEAR THE
NEXT TIME THE PANEL IS RE-ARMED.
FIRST ALARM IN
WHEN THE PANEL IS ARMED, ADDITIONAL ALARM SIGNALS SENT WILL CAUSE THIS
CONDITION. IF THE CHANNEL IS SET AS "DELAYED", THIS CONDITION WILL OCCUR
AFTER ANY DELAYS IF THE PANEL IS NOT DISARMED. DISPLAY WILL CLEAR THE
NEXT TIME THE PANEL IS RE-ARMED.
ADDITIONAL ALARMS IN
ANY TRANSMITTER THAT CAN SEND A LOW BATTERY SIGNAL WILL CAUSE THIS
CONDITION WHEN ITS BATTERY IS LOW. DISPLAY WILL REMAIN UNTIL A SIGNAL
FROM THE SAME TRANSMITTER WITH A GOOD BATTERY IS SENT.
TRANSMITTER LOW BATTERY
ANY TRANSMITTER THAT CAN SEND A TAMPER SIGNAL WILL CAUSE THIS
CONDITION WHEN IT IS TAMPERED. DISPLAY WILL CLEAR THE NEXT TIME THE
PANEL IS ARMED.
TRANSMITTER TAMPER
IF THE RECEIVER DOES NOT RECEIVE STATUS SIGNALS FROM A TRANSMITTER
THAT IS SET AS SUPERVISED, THIS CONDITION WILL BE DISPLAYED. THE RECEIVER
CAN BE SET FOR TWO OR EIGHT HOURS OF MISSING STATUS TRANSMISSIONS
BEFORE THE CONDITION OCCURS. DISPLAY WILL CLEAR THE NEXT TIME THE
PANEL IS ARMED.
TRANSMITTER STATUS ALERT
ANTENNA CONNECTOR
TYPE "F" ANTENNA CONNECTOR FOR
CONNECTION TO LOCAL OR REMOTE
ANTENNA THROUGH RG-59 COAX
MODE LIGHT
TRANSMITTER DISPLAY
CONDITION DISPLAY
MEMORY LIGHT
UP & DOWN BUTTONS
ADVANCE BUTTON
MEMORY BUTTON
TERMINAL BLOCK
LIGHTS WHEN UNIT IS
IN PROGRAM MODE,
FLASHES WHEN RF IS
RECEIVED IN RUN
MODE
SHOWS THE TRANSMITTER'S
CHANNEL NUMBER AND IS USED
DURING PROGRAMMING
WIRING KNOCKOUTS
SHOWS THE TRANSMITTER'S
CONDITION AND IS USED DURING
PROGRAMMING
LIGHTS DURING PROGRAM
MODE TO SHOW WHEN A
TRANSMITTER HAS BEEN
ENTERED OR AN OPTION
HAS BEEN SELECTED,
LIGHTS DURING RUN MODE
WHEN SYSTEM IS ARMED,
BLINKS DURING EXIT DELAY
USED DURING PROGRAMMING
TO SELECT OPTIONS AND
ENTER TRANSMITTERS
USED DURING PROGRAMMING
TO CHANGE ZONE NUMBERS
AND SELECT FUNCTIONS
PRESS EITHER TO ENTER
PROGRAM MODE, UP
INCREASES AND DOWN
DECREASES VALUE DISPLAYED
PRESS TOGETHER TO EXIT
PROGRAM MODE
FOR WIRING CONDUIT
CONNECTION
CONNECTIONS FOR ZONE AND
SUPERVISORY OUTPUTS,
POWER AND ARMED INPUTS
TEST POINTS
AUDIO TEST
POINTS FOR
LISTENING TO
RADIO INPUT
WITH BUTTSET
WRONG!
RIGHT
CENTRALLY LOCATE RECEIVER
OR ANTENNA
TRANSMITTERS AT THE OTHER END OF
HOUSE MIGHT BE TOO FAR AWAY
BASEMENT
BASEMENT
RCVR
RCVR
RIGHT
WRONG!
LOCATING A RECEIVER OR ANTENNA BELOW
EARTH LEVEL WILL IMPAIR RANGE
MOUNT RECEIVER OR ANTENNA AS HIGH ABOVE
EARTH LEVEL AS POSSIBLE
90% - 100%
OF FULL POWER
65% - 95%
OF FULL POWER
10% - 70%
OF FULL POWER
WALLBOARD AND
WOOD STUDS
CONCRETE WITH STEEL
REINFORCEMENT OR
METAL LATH AND PLASTER
LIGHT CONCRETE
OR BRICK
TX
Concrete
slab
floor
DOOR
TX
Concrete
slab
floor
DOOR
Less
than
3 ft.
above
slab
Min.
3 ft.
RIGHT
WRONG!
TX
Wall
WRONG!
Large
metal
appliance
(refrig.)
CONSTRUCTION
MATERIALS WILL
EFFECT RADIO RANGE
RECEIVER (ANTENNA)
LOCATION EFFECTS
RADIO RANGE
TRANSMITTER
MOUNTING WILL
EFFECT RADIO
RANGE
ATTACH CASE WITH
TWO SCREWS IN
KEYHOLE SLOTS,
THEN SECURE CASE
WITH TWO BOTTOM
SCREWS
7"
5"
5"
USE SCREWS AND ANCHORS TO
MOUNT THE RECEIVER
MOUNTING
PATTERN
USE LOCAL
WHIP ANTENNA
(SUPPLIED)
- OR -
USE THE
MODEL EXA-1000
REMOTE ANTENNA
(OPTIONAL)
CONNECT ANTENNA
COAX DIRECTLY OR
USE UP TO 25 FEET
OF RG-59 COAX AS
AN EXTENSION
1 2 3 4 5 6 7 8 9 1011121314151617181920
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
SXR-64A TERMINALS
ZONE OUTPUTS
LOW BATTERY OUTPUT
FOR CONNECTION TO ALARM ZONE INPUTS ON THE ALARM
CONTROL PANEL. ZONE OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL PROGRAMMED FOR THAT ZONE IS
IN THE FAULTED (ALARM/OPEN) CONDITION ("O" DISPLAYED
ON THE CONDITION DISPLAY).
STATUS OUTPUT
TAMPER OUTPUT
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL DISPLAYS A "P" ON THE CONDITION
DISPLAY OR WHEN ANY PROGRAMMING BUTTON IS
PRESSED WHILE THE SYSTEM IS ARMED.
TEST OUTPUT
POWER INPUT
ARMED INPUT
FOR CONNECTION TO THE ALARM
CONTROL PANEL'S ARMED OUTPUT.
THE ARMED INPUT CAN BE SET FOR
ARMED-POSITIVE OR
ARMED-NEGATIVE POLARITY.
NOTES:
1. ALL COM TERMINALS ARE COMMON GROUND
AND CONNECTED TOGETHER.
2. ALL OUTPUTS CAN BE PROGRAMMED FOR NORMALLY
OPEN OR NORMALLY CLOSED OPERATION. EACH OUTPUT
RETURNS TO ANY COM TERMINAL.
3. EACH OUTPUT CAN SWITCH UP TO 100 mA @ 24 VDC
MAXIMUM.
FOR CONNECTION TO A TEST ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER THAT CAN SEND A TEST SIGNAL HAS ITS
TEST BUTTON PRESSED.
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL DISPLAYS AN "S" ON THE
CONDITION DISPLAY.
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL DISPLAYS AN "L" ON THE
CONDITION DISPLAY.
FOR CONNECTION TO THE ALARM
CONTROL PANEL'S AUXILIARY
POWER OUTPUT. POWER INPUT
CAN BE FROM 11-16 VDC ONLY
1 2 3 4 5 6 7 8 9 1011121314151617181920
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
SXR-64A TERMINALS
END-OF-LINE
RESISTORS
ALARM CONTROL PANEL
8
ZONE 1
COMMON
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZONE 7
ZONE 8
COMMON
COMMON
COMMON
AUXILIARY
POWER
ARMED
OUTPUT
OUTPUTS PROGRAMMED
FOR NORMALLY OPEN
CHANNEL
SWITCH
SYSTEM
SWITCH
SET CHANNEL AND
SYSTEM SWITCH TO
ANY UNIQUE CODE
EACH S1 FORMAT
TRANSMITTER MUST
BE SET TO A DIFFERENT
CODE
MODEL ST
MODEL ST-1
CHANNEL
SWITCH
SYSTEM
SWITCH
MODEL 50S40A
WHEN UPGRADING AN SS-32,
SSR-32, OR SXR-64 INSTALLATION,
THE TRANSMITTER SWITCH
SETTINGS CAN REMAIN THE SAME
ST-1 & 50S40A NOTE: SET SXR-64A TRANSMITTER OPTION "A"
TO "ON" FOR THE CHANNEL THE TRANSMITTER IS PROGRAMMED TO.
OTHERWISE, THE LONG ALARM AND RESTORE
TRANSMISSIONS WILL CAUSE A DOUBLE ZONE CLOSURE
SYSTEM
SWITCH
CHANNEL
SWITCH
MODEL ST-23A
ST-23A NOTE: SET
SYSTEM SWITCH #1
TO OFF
STATUS
JUMPER
RESTORE
JUMPER
CUT ST-1 JUMPERS
TO ENABLE STATUS
& RESTORE SIGNALS
CHANNEL
SWITCH
SYSTEM
SWITCH
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Installation Instructions

SXR-64ASupervised Wireless Receiverand Zone ExpanderInstallation InstructionsINTRODUCTIONThe Model SXR-64A is a 64-channel, 12-zone, supervised wirele

Page 2 - CADDX RANGER 9000

Copyright © 2003 Linear Corporation 220822 AERASING SINGLE-CHANNEL TRANSMITTERS ERASING MULTI-BUTTON TRANSMITTERS SETTING RECEIVER OPTIONSTRANSMITTER

Commentaires sur ces manuels

Pas de commentaire