GE Security g Manual test The NX-4 can be programmed to perform a bell and/or communicator test; to do this, enter [*]-[4]-[4] while the sy
GE Security g Swinger shutdown This feature allows one or more zones to be bypassed automatically after a specified number of alarms. If im
GE Security g PROGRAMMING THE NX-4 KEYPADS Programming the LED keypads This section describes how to program the address and partition for
GE Security g [*]-[9]-[4] SET KEYPAD NUMBER AND PARTITION 1. Enter [*]-[9]-[4]-[program code]- the “Service” LED and the “Instant” LED
GE Security g [*]-[5] CHANGING USER CODES 1. Enter [*]-[5]-[master code]- the “Ready” LED will flash. 2. Enter the 2 digit user
GE Security g NOTE: ANY MASTER ARM/DISARM CODE CAN ADD OR CHANGE A USER CODE IF THE MASTER CODE HAS ACCESS TO THE SAME PARTITIONS AS THE CO
GE Security g Programming the NX-148 LCD keypads This section describes how to program the address and partition for each keypad, and it al
GE Security g [*]-[9]-[3] SET KEYPAD OPTIONS 1. Enter [*]-[9]-[3] The LCD screen will prompt for a code. 2. Enter [program code] The L
GE Security g Remark : In the menu “Select an option” 8 additional options can be selected. The options 5 until 8 are not used for the mo
GE Security g Keypad functions for the NX-148 LCD keypad The LCD keypads have a bilingual user’s interface. As a result, you can simply sel
GE Security g CONTENTS CONTENTS...
GE Security g [*]-[9]-[0] READING THE EVENT LOG The NX-4 has a 512-event log which can be retrieved using a master code. This log contain
GE Security g [*]-[▲] VIEW ZONE STATUS 1. Enter [*]-[▲] The LCD screen will display the zone status. 2. Use the ‘up’ and ‘down’ scroll
GE Security g [*]-[6] ASSIGNING AUTHORITY LEVEL Note: You must be authorized to access the partition that you wish to add to, or remove
GE Security g [*]-[CHIME] ACTIVATING WALKTEST 1. Enter [*]-[CHIME] The LCD screen will prompt you for a “master code”. 2. Enter [master
GE Security g PROGRAMMING THE NX-4 CONTROL PANEL Programming the NX-4 control panel via the LED keypad ENTERING THE PROGRAM MODE To enter
GE Security g EXITING THE PROGRAM MODE When all the desired changes in programming have been made, it is time to exit the program mode. Pr
GE Security g LOADING FACTORY DEFAULTS To load the factory defaults, enter the program mode using the procedure on page 24, then type [9]-[
GE Security g PROGRAMMING EXAMPLE (Feature selection data) Location 23, segment 1 1 = Quick arm 2 = Re-exit 3 = Auto bypass 4 = Silent k
GE Security g Programming the NX-4 control panel via LCD keypad ENTERING THE PROGRAM MODE To enter the program mode, press [*]-[8]. The LC
GE Security g CHARACTER DATA: Character data is used to enter LCD text when programming (see [*]-[9]-[2] feature for custom messages). Cust
GE Security g NX-4 PROGRAMMING WORKSHEETS ...
GE Security g ALPHANUMERIC CHARACTER TABEL 1 A 20 T 39 ä 58 n 77 # 2 B 21 U 40 ä 59 o 78 $ 3 C 22 V 41 b 60 ô 79 & 4
GE Security g IMPORTANT REMARKS Tamper memorization If location 37 segment 6 option 8 is set, tamper alarm indications (zone tampers an
GE Security g CONTROL PANEL PROGRAMMING LOCATIONS ) For most routine installations, the “Quick Start” option will allow for enabling a maj
GE Security g Segment 2- Phone N° 1 backup control: Programming a “0” in segment 2 of this location will cause the NX-4 to make the designa
GE Security g Reporting events to phone number 1 Phone N°1 has two programming locations that are used to select the events which are repor
GE Security g Telephone number 2 LOCATION 6 - PROGRAMMING PHONE N° 2 (20 segments, numerical data) Phone N°2 is programmed in location 6.
GE Security g Reporting events to phone number 2 Phone N°2 can be used to back up phone N°1, or as a second receiver to multi-report or s
GE Security g Telephone number 3 LOCATION 12 - PROGRAMMING PHONE N° 3 (20 segments, numerical data) Phone N°3 is programmed in location 12
GE Security g Reporting events to phone number 3 Phone N°3 can be used as a third receiver to multi-report or split report events. Phone N
GE Security g Special formats LOCATION 18 - CUSTOM COMMUNICATOR FORMAT (see locations 2, 8, and 14) Segment 1 1 = On for 1800hz transmit;
GE Security g GENERAL INFORMATION The NX-4-EUR (from now on called NX-4) NetworX from Caddx represents a new approach to the design of se
GE Security g Download parameters ) LOCATION 19 - DOWNLOAD ACCESS CODE (8 segments, numerical data) Location 19 contains the eight-digit ac
GE Security g Feature and report selections (for partition 1) ) LOCATION 23 - PARTITION 1, FEATURE AND REPORT SELECTIONS (5 segments, feat
GE Security g Segment 5 1 = Reserved 2 = Reserved 3 = Reserved 4 = Reserved 5 = Reserved 6 = Reserved 7 = Reserved 8 = Reserved E
GE Security g Zone configurations and partition selection DEFAULT ZONE CONFIGURATIONS Zones can be programmed to be one of thirty different
GE Security g 12 2 INTERIOR FOLLOWER WITH “CROSS ZONE” ENABLED This zone will be instant when the system is armed and no entry or exit de
GE Security g 24 2 INSTANT ZONE WITH CHIME ENABLED A trip will create an alarm when the system is armed. When the control panel is disarme
GE Security g ) LOCATION 25 - ZONES 1-8 CONFIGURATION GROUP (8 segments, numerical data) Location 25 contains the configuration group (zone
GE Security g Segment 4 1 = On: if fail to communicate report is enabled 2 = On: if log full report is enabled 3 = On: if autotest
GE Security g LOCATION 40 - SYSTEM TIMERS (14 segments, numerical data) Location 40 contains the duration of various system timing function
GE Security g LOCATION 43 - GO TO PROGRAM CODE PARTITION AND AUTHORIZATION (2 segments, feature selection data) The “Go To Program Code”
GE Security g FEATURE DEFINITIONS Abort If this option is enabled, the NX-4 will wait the programmed number of seconds (0-255) in locati
GE Security g Programming the outputs LOCATION 45 – Reserved LOCATION 46 - AUXILIARY OUTPUT 1-2 SPECIAL TIMING (2 segments, feature select
GE Security g AUXILIARY OUTPUT EVENT SELECTION DATA EVENT DATA EVENT 09 Burglary alarm 289 Expander trouble 19 Fire alarm 29 Dynam
GE Security g Setup for auto-test, auto-arm and opening/closing times LOCATION 51 - AUTOTEST CONTROL (4 segments, numerical data) Segment 1
GE Security g LOCATION 54 - DAYS OF THE WEEK “ARM ONLY AFTER CLOSE WINDOW” CODES (1 Segment, feature selection data) Location 54 selects t
GE Security g Communicator codes for slow speed formats only LOCATIONS 56-83 ARE ONLY USED WHEN REPORTING EVENTS TO A PAGER, OR WHEN USING
GE Security g LOCATION 59 - TROUBLE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical data) Location 59 contains the even
GE Security g LOCATION 64 - KEYPAD AUXILIARY 2 COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments, numerical data) Location 64 contains
GE Security g LOCATION 69 - LOW BATTERY / LOW BATTERY RESTORE COMMUNICATOR CODES, SLOW SPEED FORMATS ONLY (4 segments, numerical data) Loca
GE Security g LOCATION 76 - LOG FULL COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments, numerical data) Location 76 contains the ten
GE Security g LOCATION 80 - RECENT CLOSING AND EXIT ERROR COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments, numerical data) Loca
GE Security g Auxiliary power overcurrent The NX-4 will light up the “Service” LED on the keypad whenever too much current is being drawn
GE Security g Programming zone configuration groups LOCATIONS 110-169 ARE USED TO CHANGE THE ZONE CONFIGURATIONS AS LISTED IN THE TABLE ON
GE Security g Segment 4 1 = On: enables zone activity monitor 2 = On: enables end of line resistor defeat on non-fire/non-keyswitch zones
GE Security g LOCATION 117 - CONFIGURATION GROUP 4 CHARACTERISTIC SELECT (5 segments, feature selection data) Use the “Configuration G
GE Security g LOCATION 124 - CONFIGURATION GROUP 8 ALARM EVENT CODE (1 segment, numerical data) Location 124 contains the event code that i
GE Security g LOCATION 131 - CONFIGURATION GROUP 11 CHARACTERISTIC SELECT (5 segments, feature selection data) Use the “Configuration G
GE Security g LOCATION 138 - CONFIGURATION GROUP 15 ALARM EVENT CODE (1 segment, numerical data) Location 138 contains the event code that
GE Security g LOCATION 145 - CONFIGURATION GROUP 18 CHARACTERISTIC SELECT (5 segments, feature selection data) Use the “Configuration
GE Security g LOCATION 152 - CONFIGURATION GROUP 22 ALARM EVENT CODE (1 segment, numerical data) Location 152 contains the event code that
GE Security g LOCATION 159 - CONFIGURATION GROUP 25 CHARACTERISTIC SELECT (5 segments, feature selection data) Use the “Configuration
GE Security g LOCATION 166 - CONFIGURATION GROUP 29 ALARM EVENT CODE (1 segment, numerical data) Location 166 contains the event code that
GE Security g Configuration groups The NX-4 has 30 configuration groups that determine how each zone will function and report. The default
GE Security g LOCATIONS 207-211 - RESERVED LOCATION 212 – PROGRAMMING THE LCD KEYPAD ADDRESS (1 segment, numerical data) When using the X
GE Security g NX-4 PROGRAMMING WORKSHEETS (Factory defaults for NX-4-EUR (BEL/POL) are in bold italic text) LOC PG DESCRIPTION DEFAUL
GE Security g 12 37 PHONE 3 14-14-14-14-14-14-14-14-14-14-14-14-14-14-14-14-14-14-14-14 13 37 PHONE 3, ACCOUNT CODE 10 – 10 – 10 – 10
GE Security g PARTITION 1, FEATURE SELECTION Segment 1 Segment 2 Segment 3 1 Quick Arm 1 LED extinguish enable 1 Open/Close 2 R
GE Security g SIREN AND SYSTEM SUPERVISION Segment 1 (Circle Numbers To Program) 1 Siren sounds for telephone line cut while armed 2 S
GE Security g 38 47 SWINGER COUNTDOWN COUNT 0 KEYPAD SOUNDER CONTROL Segment 1 (Circle Numbers To Program) 1 Keypad sounds for Teleph
GE Security g 42 48 GO TO PROGRAM CODE 9-7-1-3-0-0 GO TO PROGRAM CODE PARTITION AND AUTHORIZATION Segment 1 (Circle Numbers To Prog
GE Security g DAYS OF THE WEEK WHEN “ARM ONLY AFTER CLOSE” WILL BE ABLE TO ARM/DISARM 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday
GE Security g OPENING CODE COMMUNICATOR CODE Segment 1 Opening Code for Codes 1-8 0 77 58 Segment 2-8 Reserved 0 CLOSING COMMUNICA
GE Security g 122 62 CONFIGURATION GROUP 7 ALARM EVENT CODE 0 123 62 CONFIGURATION GROUP 7 CHARACTERISTIC SELECT 2-5-278 124 63
GE Security g Exit error If this option is enabled, the NX-4 will send an “Exit Error Report” when an entry/exit zone is faulted, at the i
GE Security g DAYS OF THE WEEK WHEN “AUTO DISARMING” WILL OCCUR Sunday Monday Tuesday Saturday Wednesday Thursday Friday Reserved 206
GE Security g NX-4 WIRING DIAGRAM Z1Z2Z3Z4COMCOMSIRENZONESAUX2SMOKE+ACACT1 T R R1POS (Aux Pwr +)COM (Aux Pwr -)DATAEARTHLIGHTNING PROTEC
GE Security g TERMINAL DESCRIPTION TERMINAL DESCRIPTION R1 House Telephone Ring. R Telephone Ring. T Telephone Tip. T1 House Tele
GE Security g TECHNICAL SPECIFICATIONS Technical specifications NX-4 Operating power - Nominal 16.5 Vac, 50/60Hz, 35VA - Minimum/maxim
GE Security g Technical specifications NX-1308, NX-1316, NX-1324 Operating power - Nominal 12 Vdc - Minimum/maximum 9 Vdc - 1
GE Security g APPENDIX 1: REPORTING FIXED CODES IN CONTACT-ID AND SIA The table below lists the event codes sent for the following repo
GE Security g THE NUMBER IN PARENTHESES FOLLOWING THE EVENT IS THE NUMBER THAT WILL BE REPORTED AS THE ZONE NUMBER. IF THERE ARE NO PARENTH
GE Security g APPENDIX 2: REPORTING ZONE CODES IN SIA OR CONTACT ID The NX-4 has the ability to report SIA level 1 transmissions to eit
GE Security g The NX-4 can report Ademco Contact ID transmissions. Each report in Contact ID consists of an Event Code and a Zone ID. The
GE Security g APPENDIX 3: EXPANDER NUMBERS FOR REPORTING EXPANDER TROUBLE The tables below list the device numbers that will be reported f
GE Security g Immediate restore by zone The NX-4 can be programmed to send alarm and restore reports as soon as they occur, or to wait unt
GE Security g CE DECLARATION NX-4-EUR Installation manual Page 90 08/09/04
NX-4-EUR Installation manual Page 91 08/09/04 GE Security g
GE Security g NX-4-EUR Installation manual Page 92 08/09/04 GE Security g NX-4-EUR Installation manual Page 92 08/09/04
NX-4-EUR Installation manual Page 93 08/09/04 GE Security g
www.gesecurity.com COPYRIGHT ©2004 EMEA Distribution is a division of GE Security EMEA bvba © GE
Commentaires sur ces manuels