AUXILIARY OUTPUT EVENT SELECTION
DATA EVENT DATA EVENT
0 // Burglary Alarm 26 Fire Trouble
1 // Fire Alarm 27 Chime
2 // 24 Hour Alarm 28 // Expander Trouble
3 // Trouble Alarm 29 Dynamic Battery Test Time
4 // Tamper Alarm 30 Open Period
5 Yelping Siren (Burglary) 31 Closed Period
6 Temporal Siren (Fire) 32 Listen-In
7 Any Siren 33 Line Seizure
8 Any Bypass 34 Ground Start
9 AC Fail 35 Fail To Communicate
10 Low Battery 36 Reserved
11 // Duress 37 Program Mode
12 // Aux 1 Keypad Zone 38 Download In Process
13 // Aux 2 Keypad Zone 39 Reserved
14 // Panic Keypad Zone 40 Short Circuit (Over-current)
15 Keypad Tamper 41 Box Tamper
16 // Autotest 42 Siren Tamper
17 Alarm Memory 43 Any Open
18 Entry 44 Any Short
19 Exit 45 Any Fault (Open/ Short on Non-Fire Zone)
20 Entry or Exit 46 // Any Alarm
21 Armed State 47 Beeping Keypad
22 Disarmed State 48 // Code Entry (See note below)
23 Ready 49 ˜˜ // Key FOB Function 1
24 Not Ready 50 ˜˜ // Key FOB Function 2
25 Fire
Notes: When Event 48 is programmed, it is possible to program a user code's authorization to select which output(s)
a particular code will activate. When LED 8 is on for an authorization, then LEDs 1- 2 correspond to that code
activating outputs 1 & 2 respectively. (See programming the LED keypads on page 8.)
˜ Events 49 & 50 require NX-408, NX-416, or NX-448 wireless receivers to operate.
// If set to follow condition, these events will be 1 second.
LOCATION 51 - AUTOTEST CONTROL (4 segments, numerical data)
Segment 1: Program a "1" if the interval is to be in hours; Program a "0" if in days. Add a A2" to suppress the
daily test or a A3" to suppress the hourly test if any report has been sent.
Segment 2: Program the Autotest interval from 1-255 hours/days.
Segment 3: Program the Autotest report hour in 24-hour format (if the interval is in hours, this segment is
ignored).
Segment 4: Program the Autotest report time, number of minutes after the hour.