NX-4 Control
Page 37
TERMINAL DESCRIPTIONS
DESCRIPTION
R1 House Telephone Ring (Grey).
R Telephone Ring (Red).
T Telephone Tip (Green).
T1 House Telephone Tip (Brown).
AC AC input. Connect to a 16.5V 25, 40 or 50 VA Class ll U.L. approved transformer.
EARTH Earth Ground. Connect to a cold water pipe or a 6 to 10 foot driven rod.
AUX 1
Connect negative lead of low current device [relay, LED (install 1K resistor in series with LED), etc.].
Connect positive lead of device to KEYPAD +. Current is limited to 250mA when output is negative, and
250FA when output is positive.
SIREN
If used as a siren output (default), the speaker rating should be 15 watt at 8 or 16 ohm, or 30/40 watt
at 4, 8, or 16 ohms. If voltage output is selected in location 37, this output becomes voltage output,
12VDC, 1 Amp maximum load. NOTE: A 3.3K resistor may be required across the bell terminals
when a 12 VDC siren is used. If no resistor is used, you may experience voltage leakage into
the siren, which will cause these devices to output a small signal.
COM Connect negative wire of siren/speaker or voltage output devices.
SMOKE+
Smoke detector power 12VDC, 250 mA maximum (For those jurisdictions which allow the Priority zone
to be used with smoke detectors.)
AUX 2
Connect negative lead of low current device [relay, LED (install 1K resistor in series with LED), etc.].
Connect positive lead of device to KEYPAD +. Current is limited to 250mA when output is negative, and
250FA when output is positive.
KEYPAD
DATA
Connect to the data terminal on the keypads and the expanders. MAXIMUM: 8 keypads + 1 other
device.
COM
Connect to the Common terminal on the keypads, expanders, and other power devices.
POS
AUX PWR
+
Connect to the Positive terminal on the keypads, expanders, and other power devices. This terminal
is limited to 1 amp total current.
ZONE 4
Connect to one side of zone 4 loop. Connect the other side to com terminal. Open or short causes alarm.
COM Common (-) terminal for zones 3 & 4.
ZONE 3
Connect to one side of zone 3 loop. Connect the other side to com terminal. Open or short causes alarm.
ZONE 2
Connect to one side of zone 2 loop. Connect the other side to com terminal. Open or short causes alarm.
COM Common (-) terminal for zones 1 & 2.
ZONE 1
Connect to one side of zone 1 loop. Connect the other side to com terminal. Open or short causes alarm.
KEYPAD MAXIMUM WIRE RUN
(Note: These numbers are for one keypad at the end of the wire. When connecting more than one keypad to the end
of the wire, a higher gauge wire will be required.)
WHEN CONNECTED TO NX-4 WHEN CONNECTED TO NX-320
Length in feet Wire Gauge Wire Gauge
250 24 22
500 20 18
1000 18 16
1500 16 14
2500 14 12