CADDX NX-6 Manuel d'installation Page 44

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 104
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 43
GE Security
g
Feature and report selections (for partition 1)
) LOCATION 23 - PARTITION 1, FEATURE AND REPORT SELECTIONS (5 segments, feature
selection data)
Location 23 is used to enable certain features that the user can access or see from the
keypad of the system. In addition, certain communicator reports are enabled in location
23. Each of these features can be enabled by partition. For additional partition
information, see locations 88-109.
If the feature selection location for any partition is left blank, that partition will use this
location for the feature selection.
This location contains 5 segments of 8 features each (see the feature definitions).
Segment 1
1 = On: enables the quick arm feature (for exit and stay mode)
2 = On: enables the re-exit feature
3 = On: enables the automatic bypass feature (of interior zones)
4 =
On: enables the silent keypad panic feature (overrides the audible
panic selection)
5 = On: enables the audible keypad panic feature
6 = On: enables the keypad Aux 1 feature (FIRE)
7 = On: enables the keypad Aux 2 feature (MEDICAL)
8 =
On: enables the keypad multiple code attempt tamper feature
(keypad lockout)
Segment 2
1 = On: enables the LED extinguish feature
2 = On: enables the require code for bypassing feature
3 = On: enables the zone bypassed sounder alert feature
4 = On: enables the AC power/low battery sounder alert feature
5 = On: enables bypass toggle
6 = On: enables silent auto arm
7 = On: enables the automatic instant feature (of entry/exit zones)
8 = On: enables final set door
Segment 3
1 = On: enables opening and closing reports
2 = On: enables zone bypass reporting
3 = On: enables zone restore reporting
4 = On: enables zone trouble reporting
5 = On: enables zone tamper reporting
6 = On: enables the cancel reporting
7 = On: enables the recent closing report
8 = On: enables the exit error report
Segment 4
1 = On: enables late to close / early to open reporting
2 = On: enables auto arm in STAY mode
3 =
On: enables instant NIGHT mode (applies to NX-1208E / NX-
1248E: no toggle)
4 = On: tamper when sensor lost if armed
5 = On : enables instant STAY mode (toggle)
6 = On : arming allowed with tamper memory / communication failure
7 = On : arming allowed with battery trouble
8 = Reserved
NX-6-EUR Installation manual Page 44 23/12/04