FEATURE DEFINITIONS
Abort
If this option is enabled, the NX-6 will wait the programmed number of seconds (0-255) in
location 40 prior to sending an alarm. During this delay time, the “Cancel” LED will flash.
To abort the report, type in a code and press the [Cancel] key. The LED will go out. If the
report is not aborted within the allotted time, the LED will go out when the report is sent.
The dialler delay is programmed at location 40, segment 8. Each zone can be defined
as a “dialler delay zone” by defining the relevant option in segment 3 of the appropriate
zone configuration group (see locations 110-169).
AC fail / low battery report/warning
The NX-6 can be programmed to report an AC failure and/or low battery conditions to the
central station. It can also be programmed to sound the keypad immediately when the
condition is detected. The AC failure report/warning can be delayed (see locations 37, 39
and 40).
AC power / low battery sounder alert
If this option is enabled, the NX-6 will beep the keypad sounder upon arming or
disarming, if the AC power is not present or if a low battery has been detected (see
location 23, segment 2).
Arm / disarm codes
The NX-6 may have 40 four-digit or six-digit codes to arm/disarm the control panel. All the
codes must have the same number of digits. The factory default for user 1 is [1]-[2]-[3]-
[4] when using a 4-digit code, or [1]-[2]-[3]-[4]-[5]-[6] for a 6-digit code. This code can
then be used to enter the new arm/disarm codes (see location 41).
Automatic arming
If programmed, the NX-6 will Auto Arm at a specified time. At this time, the keypad will
start beeping before the panel arms and this for the amount of time set as warning time
(warning timer). The arming process will be stopped during the warning time if a code is
entered on the keypad or when movement has been detected. The NX-6 will attempt to
arm again after the amount of time set as retry time (retry timer) until the next “opening”
time (loc. 52), or until the system is armed. The panel will not try to re-arm if the retry
feature has been disabled. If a zone is faulted before the warning timer starts and stays
faulted when the panel tries to auto-arm, the zone will automatically be bypassed. The
auto arming of a partition can be programmed so that it is silent. If closing reports are
sent, the user code will be 97 (see locations 23 segment 2, location 40 segment 12 and
13 and location 52-55).
Automatic bypass / instant arming
When this option is enabled, the control panel can automatically bypass interior follower
zones if no exit is detected during the exit delay time. Entry delay zones can also be
made instant (see location 23, segments 1 and 2).
Auto-test
This feature will cause the panel to call the central station, in order to report a
communicator test at a specified interval (see location 51). Also, the auto-test report may
be enabled ONLY when the control panel is armed see location 37 segment 4).
Auxiliary outputs
The NX-6 has four programmable outputs which can be used to activate LED’s, sirens,
flashes, etc. (see the terminal description and locations 47-50).