LOCATION 152 - CONFIGURATION GROUP 22 ALARM EVENT CODE (1 segment, numerical data)
Location 152 contains the event code that is sent for a Contact ID or SIA report. The
desired event code should be chosen from the list on pages 121-122. The zone ID will be
the zone that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may
also contain the alarm report code for the Robofon format (value 00-99).
LOCATION 153 - CONFIGURATION GROUP 22 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
LOCATION 154 - CONFIGURATION GROUP 23 ALARM EVENT CODE (1 segment, numerical data)
Location 154 contains the event code that is sent for a Contact ID or SIA report. The
desired event code should be chosen from the list on pages 121-122. The zone ID will be
the zone that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may
also contain the alarm report code for the Robofon format (value 00-99).
LOCATION 155 - CONFIGURATION GROUP 23 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
LOCATION 156 - CONFIGURATION GROUP 24 ALARM EVENT CODE (1 segment, numerical data)
Location 156 contains the event code that is sent for a Contact ID or SIA report. The
desired event code should be chosen from the list on pages 121-122. The zone ID will be
the zone that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may
also contain the alarm report code for the Robofon format (value 00-99).
LOCATION 157 - CONFIGURATION GROUP 24 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
LOCATION 158 - CONFIGURATION GROUP 25 ALARM EVENT CODE (1 segment, numerical data)
Location 158 contains the event code that is sent for a Contact ID or SIA report. The
desired event code should be chosen from the list on pages 121-122. The zone ID will be
the zone that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may
also contain the alarm report code for the Robofon format (value 00-99).