Programming the outputs
LOCATION 45 - AUXILIARY OUTPUT 1-4 PARTITION SELECTION (4 segments, feature selection data)
Location 45 is used to select the partition(s) in which the events must occur before the
output(s) will activate. Location 45 has 4 segments. Segment 1 corresponds to output 1,
and segment 2 corresponds to output 2, segments 3 and 4 correspond to outputs 3 and
4.
Segment 1
(Auxiliary 1)
Segment 2
(Auxiliary 2)
Segment 3
(Auxiliary)
Segment 4
(Auxiliary)
1= Partition #1 1= Partition #1 1= Partition #1 1= Partition #1
2= Partition #2 2= Partition #2 2= Partition #2 2= Partition #2
3-8 Reserved 3-8 Reserved 3-8 Reserved 3-8 Reserved
LOCATION 46 - AUXILIARY OUTPUT 1-4 SPECIAL TIMING (4 segments, feature selection data)
Location 46 contains special timing feature activation for the 4 auxiliary outputs (relays).
Segment 1 corresponds to output 1, segment 2 corresponds to output 2. Segments 3 and
4 correspond to outputs 3-4.
Segment 1-4
1 =
On: if output should be timed in minutes; Off: if timed in
seconds
2 = On: if output should latch; Off: if output should be timed
3 =
On: if output should stop timing when the code is entered; Off:
if the output should continue to time when the code is entered
4 =
On: if output should only activate between the closing and
opening time in locations 52 and 53
5 =
On: if output should only activate between the opening and
closing time in locations 52 and 53
6 =
On: if output should be inverted (0 volts going to 12 volts when
activated)
7 = Reserved
8 = Reserved
NX-6-EUR Installation manual Page 54 23/12/04